AO188 Instrument Parameters
Parameter | Description |
---|---|
Location of the system | Nasmyth focus (IR) |
Spectral coverage | 0.9-5.3 Β΅m |
Main Optics | 2.7' FOV, F/13.9 |
Main optics throughput | 0.7 at JHKLM |
Number of control elements | 188 |
Deformable mirror | Magnetic mirror with 3228 actuators |
Tip/tilt mount stroke | Β±5'' |
High-order WFS | Curvature sensor with 188 photon counting APDs |
Low-order WFS | 2x2 Shack-Hartman sensor with 16 photon counting APDs |
Control bandwidth | > 100 Hz, 1000 corrections/sec |
NGS magnitude | -1 < R < 16.5 |
TTGS magnitude | R < 18 |
NGS isoplanatic field | 1' in diameter |
TTGS isoplanatic field | Not determined |
Laser | CW 20.0W (on-sky) at 589nm (generates R=8.5-10.0 LGS) |
Laser beam transfer optics | Mirrors (total throughput > 90%) |
Laser launching telescope | 50cm telescope attached behind the secondary |